There is a range of capacities available for bench-top centrifuges, including:

Microcentrifuges are designed to work best with low-volume tubes, have a compact footprint, and are capable of producing 14,000 to 30,000 x g for as many as 48 microtubes at once. A few conical tubes containing 15 or 50 milliliters of liquid or two plates in SBS format can be accommodated by using certain devices. There are a variety of suppliers who offer non-refrigerated and refrigerated versions, as well as various sizes of devices based on the amount of tube space they have available.
 

  • In addition to having a larger chamber for the rotor, multipurpose centrifuges are highly versatile because they can accommodate a wide variety of rotors

  • In addition to having a flexible rotor system, specific adapter systems allow for the use of a wide variety of tubes and bottles (ranging from 0

  • 2 mL to 1,000 mL) in addition to plates

  • The characteristics of the vessel have a significant impact on the top speed that can be achieved

     

The majority of rotors include additional components, such as O-rings, lid threads, and locking mechanisms, all of which need to be maintained on a routine basis in addition to the body of the rotor itself.

O-rings

O-rings are the primary line of defense against sample loss; however, they are almost always overlooked entirely. Before O-rings can be installed on a new rotor, they have to be lubricated first. Because the majority of detergents and many disinfecting agents remove the lubricant, the O-rings need to be dried and relubricated after being washed or disinfected. This is the more important of the two steps. Because O-rings deteriorate after being autoclaved and cleaned multiple times, high speed centrifuge is essential to replace them as soon as they begin to show signs of cracking or stretching.

Lid threads The threads on bucket or rotor lids need to be cleaned on a regular basis using a gentle cloth that does not contain lint in order to remove debris that has built up over time.

By applying a thin layer of grease that has been approved by the manufacturer to the threads on the rotor lid, not only does this make opening and closing the lid much simpler, but it also helps to prevent accidental cross-threading and general corrosion.

Mechanisms for locking/unlocking

Locking mechanisms, which are responsible for securing the lid to the rotor or bucket, experience wear and tear over time and are also susceptible to damage when the lids are attached or removed. If the locking mechanism has threads, they ought to be inspected on a regular basis for damage (such as nicks or wear on the thread's edges), particularly if the mechanism is threaded. A field service technician is typically able to replace the locking mechanisms if they become damaged. The longevity of the mechanism can be significantly increased if it is checked on a regular basis and cleaned using a soft cloth to remove any debris that may have accumulated. Lubrication is not typically required for these components and parts.

It is a good idea to inquire about a speedy review of all rotors whenever there is a factory-certified technician available at the location. On customer demand, the vast majority of manufacturers will also host rotor inspection clinics. Over time, rotors will start to lose their finish or show telltale signs of damage to the surface, such as small pits in the surface of the rotor, rust, or metal corrosion. Other telltale signs of damage to the surface include pits in the surface of the rotor. All of these are strong indications that a rotor requires careful inspection in order to determine its condition. In the absence of any preventative measures, microcracks may develop at the base of the pits, and corrosion may spread throughout the rotor until it fails. The finish on carbon fiber rotors can wear off over time and after repeated exposure to chemicals; however, carbon fiber rotors themselves do not corrode. Before the exterior surface of this type of rotor becomes a handling hazard, the manufacturer has the ability to refinish the rotor.

Low-speed and superspeed centrifuge rotors that have been in use for at least ten years should be subjected to a thorough inspection and possibly considered for replacement. This is especially important if the rotors exhibit any of the symptoms that were discussed in the previous section. All ultracentrifuge rotors have recommended life spans that are determined by the total number of cycles or hours that they have been used.

To be successful in virtually any endeavor, information gathering is essential. When choosing a rotor, it is essential to have a clear understanding of the volume and RCF requirements, as well as the type of separation that is required, whether it be differential, isopycnic, or rate-zonal. This will assist in determining which of the three different rotor types to select.

After the rotors have been brought into the lab, it is critical to devise a routine rotor maintenance schedule as soon as possible. Because of this, the risks associated with working in a laboratory will decrease, the rotor's lifespan will be increased, and centrifugation and contamination issues will be mitigated. Users should follow the schedule that is recommended by the manufacturer for having rotors inspected, and they should retire rotors as soon as they show signs of wear. By taking preventative measures, one can guarantee that the centrifuges and rotors will carry out the essential sample preparation function for which they were designed.