The measurement principle for UV Visible Spectroscopy, also known as a UV Vis spectrophotometer, is not overly complicated and consists of a light source, an element that disperses light at different wavelengths, a sample, and a detector. Another name for this type of instrument is a UV Vis spectrophotometer. A UV Vis spectrophotometer is one of the names that can be used to refer to this kind of instrument.

A Dual-Mode Spectrophotometer That Can Also Measure Visible LightMonochromator

Components such as mirrors, slits, and grating can be found within the monochromator device itself. This allows the device to function properly. After that, the light is concentrated onto a diffraction grating, which is then rotated in order to select individual wavelengths. After being refocused by a second set of mirrors, the light is then directed toward the sample. At this point, the sample determines whether the light is absorbed, reflected, or transmitted depending on the specific conditions. When this process is complete, the light is released from the system. The obtained monochromatic light of intensity I0 is used to irradiate a sample, which causes the sample to transmit light of intensity I, which is then measured and analyzed. The transmittance is indicated in this context by the notation I/I0, which stands for input/output. Figure 2 is an illustration of a double beam configuration, which can be achieved by employing either a fixed or dynamic beam splitter to separate a single wavelength of light into two separate beams. This can be seen in the figure. After that, it is necessary for each individual beam to pass through both a sample and a reference in order for it to be detectable. Since the optical path can be split, vis spectrophotometer is possible to simultaneously measure the light that is incident and the light that is transmitted. This is made possible by the fact that the optical path can be divided. Because of this, it is now possible to find a solution that will compensate for the effects that are brought about by variations in the light source.

The sample compartment of a single and double beam instrument is shown in the illustration that can be found below in Figure 3, which presents both of these instruments. The figure contains this particular illustration for your perusal. When using an instrument with two beams, the photometric value is determined by determining the ratio between the reference beam and the sample beam. This is done in an instrument with a double-beam configuration. Because a single beam instrument only has one beam, it is not possible to get a ratio of the intensities by using that instrument. This is due to the fact that single beam instruments only have one beam. The signal intensity the instrument that measures it with a single beam starts to decrease as time goes on, but the spectrum that is measured by the instrument that measures it with a double beam provides a consistent baseline. The operational wavelength range that is required for the application or the location where the sample's chromophore absorbs light, the required light throughput, the stability of the source, the cost of the source, and the lifetime of the source are some of the things that should be taken into consideration. Other things that should be taken into consideration include the required light throughput. In the ultraviolet region, which extends from 190 to 350 nm, a deuterium lamp is utilized, but a halogen lamp covers a significantly larger spectral range, which extends from 330 to 3200 nm. When continuous sources are used, an arc is produced, which in turn raises the energy level of the molecules that are contained within the vacuum to a higher level. This is because the energy level of the arc itself is raised to a higher level. The process of excitation starts all over again as soon as the electrons are back in their ground state, which results in a source of light that is continually being replenished. The electrons going back to their ground state is what causes the emission of photons, and as soon as the electrons are back in their ground state, the process of excitation starts all over again. As a consequence of this, continuous sources continue to supply the sample with the same amount of light even after the sample has been subjected to the monochromator's processing. In order to accomplish the task of diffracting the light into several beams, it is necessary to rotate the light to the wavelengths that have been selected.

The distance that exists between each groove is what determines not only the spectral resolution but also the diffraction order of the light, which is the number of beams that are diffracted at a given wavelength. Because wider groove spacing results in fewer orders of diffraction, the amount of light that is able to pass through is increased. Another mirror is used to refocus the light that has been diffracted by the grating onto the exit slit, which has been adjusted to account for the dispersive properties of different wavelengths of light.

Bandwidth

The light that is generated by the monochromator is not totally monochromatic; rather, it contains a wide range of wavelengths all at once within its spectrum. The wavelength of interest can be located at the triangle's apex, and the spectral bandwidth can be determined by using the triangle's full width half maximum (FWHM) value.